In dc traction systems impermissible contact voltage can occur between the return circuit and the structure ground due to operational currents and short circuit currents.
Voltage limiting device siemens.
It s best when all electrically live cable routes in the building exposed to hazards are safeguarded by suitable protection devices according to a systematic graded protection concept.
It happens when the earth fault occurs.
If surges occur for a longer period of time milliseconds to hours due to.
Tzd 1nr conducts current till the opening of high speed circuit breaker in substation and then it returns to non conductive state recovers.
Voltage limiting device tzd 1nr becomes conductive when the voltage at its terminals approaches triggering voltage.
Voltage limiting devices estra vguard.
Beginning with the end device and all the way upstream to the entry of the power lines into the building all power lines as well as the communication lines should be provided with overvoltage protection.
Our sentron protection devices are rigorously designed to meet these requirements and they offer both protection functions and ways to integrate the devices into automation environments and collect energy data.
They do not require a power supply and can be used along the railway line.
Voltage limiting device based on a mechanical breaker and additional solid state electronic switching elements e g.
Our high voltage disconnectors and earthing switches combine state of the art technology with the highest quality standards for a voltage range from 36 kv to 800 kv.
Thyristors devices of classes 1 and 2 are passive i e.
Voltage limiting device based on a mechanical breaker class 4.
Transient surges caused by lightning and switching operations in the system are limited by the mo arrester.
It is important to ensure high system availability and optimize energy consumption while protecting people and plants.
Voltage limiting device hvl consists of the parallel connection of a metal oxide mo surge arrester with no spark gaps and two anti parallel connected thyristors.
Sécheron s vguard voltage limiting device is built on proven technologies and meets the electrical safety and internal arc testing requirements in the en 50122 1 and en 50526 2 standards.
Voltage limiting devices bvl 50 120 r01 bvl 100 120 r01 voltage limiting device vld of class 2 2 and a surge protective device spd of type 1 and 2 bvl 50 bvl 100 provides the temporary connection be tween the return circuit and the earth of the railway electric traction system during the permissible value of touch voltage is exceeded.